Product Category
The company is based on establishing a specialized
RECOMMENDED PRODUCTS
The company is based on establishing a specialized
Professional refrigeration equipment supplier
Suzhou Coresun Refrigeration Co., Ltd. was established in 2012, focusing on the production of commercial stainless steel refrigeration equipment. The company integrates R&D, production, sales and technical services. Products include Upright cabinet series, Counter series, Saladette series, Pizza bar counter series + VRX series, ABS series, Backbar Cooler series.,etc. The company has passed ISO9001: 14000 and BSCI certification to ensure the stability of product quality.
Creation Time
Enterprise Area
Employees
Patent
TECHNOLOGY
The company is based on establishing a specialized
Intelligent Control
Real time monitoring of the operating status and environmental parameters of refrigeration equipment using sensors, such as temperature, humidity, pressure, etc., and intelligent analysis and control through microprocessors.
Sealing & Insulation
Adopting advanced sealing materials and structures, such as rubber seals, mechanical seals, welding seals, etc., to ensure that the refrigeration system can maintain good sealing performance under different working conditions.
Frequency Conversion
By changing the power supply frequency of the compressor motor, the speed of the compressor is automatically adjusted according to the change in cooling load, thereby
Refrigeration Cycle
The refrigerant is compressed by a compressor to increase its pressure and temperature, and then cooled by heat dissipation in the condenser, becoming a high-pressure liquid. After being depressurized by a throttling device, it enters the evaporator, where it absorbs heat and evaporates, thus achieving the refrigeration effect.
ADVANTAGE
The company integrates research and development, production, and marketing, adhering to the principles of high starting point, high standards, and high quality, to create high-end commercial refrigeration products that strive for excellence for global customers. With its own strength, reliable product quality, and attentive service, it has won high praise and trust from domestic and foreign manufacturers
Market Strategy
By establishing strategic partnerships with overseas clients and expanding into overseas markets, the main markets currently include Europe, the Middle East, Australia, South Africa, and others.
Production Management
In terms of production management, the company is committed to a talent strategy by introducing high-end talents and relying on the ISO: 9001 management system to establish a comprehensive quality management system for all employees
Patent Information
The company is committed to occupational health and green environmental protection, and has obtained OHSAS1 8000 certification and ISO14000 system certification.
BLOG & NEWS
The company is based on establishing a specialized
Choose the Right Commercial Fridge Capacity: One Formula Cuts Operating Costs
Labour rates in the Netherlands hit €90/hour. A compressor swap in London can cost £900. Here's why more European importers are switching to modular refrigeration systems.
Discover why more European importers are choosing Suzhou for commercial refrigeration manufacturing. From stainless steel processing and CE compliance to supply chain efficiency and fast Shanghai port access.
A. Why does the compressor produce overload protection? Overload protector working principle and classification of the compressor for air conditioning overload protector is generally a sudden jump bimetal protector, by heating wire, bimetal and two static contact circuit, connected in series in the compressor circuit. When the current in the circuit is too high, the heating wire hot, baking disc-shaped bimetal, when the bimetal heats up will arch in the opposite direction, so that the contact is disconnected; when the compressor shell or motor temperature is too high, even if the working current is normal, the heating wire generates very little heat. Bimetal will also be deformed upward bending, from the two static contacts, the circuit will be cut off. This protector can automatically reset, with over-current, over-temperature double protection. Second, the working principle of the overload protector and classification 1, the working principle of the overload protector a, the general refrigeration system used in the refrigeration compressor overload protector are used to jump bimetal protector. b, this protector is mainly composed of heating wire, bimetal and two static contacts of a complete circuit, and then connected in series to the circuit where the refrigeration compressor. c. The working principle is that when the current inside the system circuit increases for no reason, the heating wire will generate a lot of heat. When the bimetal is baked under the heat of the heating wire, it will become reverse arched, so as to achieve the purpose of disconnecting from the electric shock and cutting off the whole circuit. d, even if the current in the circuit is very small, but the refrigeration compressor casing or motor temperature is too high, it will produce the same phenomenon. Thus effectively protect the safe operation of the refrigeration compressor. More convenient is that this protection can be automatically reset, so the use of the process is very convenient. 2, the classification of overload protector In general, the overload protector is classified according to the different ways of installation, mainly divided into two types of external and built-in overload protector. a、Introduction of external overload protector external overload protector is generally installed in the refrigeration compressor shell on the sealed terminals, to keep close to the upper cover, so as to ensure sensitive perception of temperature abnormalities on the refrigeration compressor shell. Because there is a process of conduction and convection from the heat transfer from the motor to the refrigeration compressor casing, there is still a process from the casing heating up to being sensed by the overload protector, so the accuracy and reliability of this method is not particularly good. Therefore, external overload protectors are used in large numbers because they are simpler and cheaper to manufacture. At the same time, the external overload protector has obvious advantages such as easy installation and maintenance, so it is used more in some small power electrical aspects. b、Integrated overload protector related introduction Built-in overload protector is subdivided into two types of tied and plugged: tied overload protector as the name implies is tied to the motor coil, so as to play a direct induction coil temperature changes, the advantage of this protector is very sensitive and accurate response. Plug-in overload protector is the installation of the protector is directly plugged into the sealed terminals, the main principle is to sense the temperature of the motor through the heat conduction of the refrigerant is normal. This protector has certain limitations, that is, in the case of no leakage of refrigerant is very sensitive, but if there is leakage of refrigerant, this protector is also virtually useless. Therefore, in general: external overload protector in the use of the effect is relatively less sensitive, accurate, and much less reliable than the built-in, but its cost is relatively much lower, so there is a certain market space. However, compared with the built-in type, the scope of adaptation is still much smaller. But the cost of the built-in overload protector is several times higher than the external type. Therefore, friends can make the corresponding choice according to their own conditions and requirements. Third, the overload protector in the use of the process of attention a, refrigeration compressor overload protector according to its different configuration, for the refrigeration compressor protection role is completely different, the overall built-in overload protector sensitivity and accuracy are much higher than the external overload protector, so it for the refrigeration compressor protection role is also much larger;. b, in the case of insufficient refrigerant or leakage, the protection effect of the two overload prote